22 Channel Datalogger with Alarms (DD-400)

DC/Current/Frequency/Status Recorder
Wide Range < 1µV to 2.5V (90 nV Resolution)
22 Channels
Battery / AC Power Operation
Upto 2 Year Battery Life
Wireless Ready
ANSI 12.18, Satellite and Modbus (Push and Poll)
Graphing and Reporting Via the Web (ViewDataNow Web Service) or Local PC (Data Dolphin Software)
Non-Volatile Flash Memory
Universal Sensor Interface
 

Interconnection Weir Monitoring
Wireless Datalogging
 

The Data Dolphin provides the accuracy of a laboratory instrument in the harsh conditions of the field environment. The ultra-high resolution 24 bit analog to digital section provides 8 single ended inputs or 4 differential bipolar inputs (or a combination of both) with resolution down to 90 nanovolts (.00000009 volts). This allows most sensors to be directly connected without any signal conditioning. It's wide range of input voltages allows for you to attach a wide range of different input types. There are an additional four inputs that can be user selected as pulse, status, event start/stop or analog inputs.

Data is stored in a non-volatile flash memory module that gives long term storage without the fear of losing your data because of dead batteries. Data is stored inside a database structure, which allows you to add or delete inputs "on the fly" without having to restart the datalogger. Even the sample rate can be changed without restarting.

Designed for field use it’s operating temperature range goes from – 40°C to over 75°C and all inputs have static protection. It is powered internally by three "C" size alkaline batteries, however there is an adapter input for 120 VAC operation and an optional coin cell battery to keep the clock operating when the "C" battery pack is being exchanged. An external 12 volt source such as a rechargeable battery and/or solar panel can be connected. The Data Dolphin’s extremely low operating current gives the datalogger an expected battery life of approximately 3 years (5 min sample rate).

Data collection, programming and viewing collected data is a breeze with the Data Dolphin Software. It allows you to view the current status, setup the logger, and generate graphs. You can also export your data to other programs for more detailed analysis and presentations. Support for ANSI 12.18, Modbus, and Internet protocols


DD-400   Specs   Literature   Software
 
DD-400 Specifications

Analog Inputs
Channels8 Single Ended Analogs or
4 Differentials or
Combination of both
(1 Differential = 2 Analogs)
5 - 10-bit Single Ended Analog
3 - Frequency
4- Counter/Status
2 - Totalizers
Maximum Input Voltage0 V to +2.5 V (0-20mA*)
Analog Voltage Resolution1 µV
A/D Bits24
Input Impedance20 Gohm
Scan Interval3 to 100 Hz
Excitation Channels2
Excitation Voltage 1+2500 mV
Excitation Voltage 2+5000 mV
Digital Inputs / Outputs
Event start/stop or
pulse channels
5
Power Requirements
Quiescent Current< 400 µAmp (Typical)
Processing current3 mA
Memory
Flash memory4 MB Flash
Data values stored233,472 (1 Precision Input)
Operating Temperature Range
Standard-40 to +60°C
Extended-55 to +80°C
Enclosure
Extruded Aluminum
Dimensions
Size (inches)8 x 3 x 3.5
Size (cm)20.32 x 7.62 x 8.89
Weight:
DD-400 with radio module,
battery and antenna
0.918kg (2.024lbs)
DD-400 with battery
pack only
0.778kg (1.715)
DD-400 alone0.564kg (1.243lbs)
 
Computer Requirements
Computer486 or higher
Operating SystemMicrosoft Windows 98,
NT, 2000, XP
RAM16MB or higher
MonitorVGA; SVGA recommended
Hard disk space25MB install only; 35MB optimal
Optional Communications
Telephone Modem
Built in Modem (CDPD, CDMA 1X, GPRS)
External Echo III Modem
Direct Cable RS-232
Spread Spectrum Radio
Licensed Radio
Extended Options
Upto 4 4-20 mA Outputs
Upto 4 Relays
LCD Display (4 Line x 20 Characters)
DST Sensor Interface Card
Enclosure
Hinged Fiberglass Case
Hinged Metal Box
Solar Panel
12 Volt 18 AHr Lead Acid Battery

DD-400   Specs   Literature   Software
 
Literature

Manuals
 Data Dolphin Software Manual (Revision: 1.3)
Tech Notes
 D40101 - Connecting the ThetaProbe
 D40102 - Connecting a 4-20 mA sensor
 D40104 - Connecting an Anemometer
 D40301 - Installing the Enfora Modem Module
 DD0302 - Replacing the Data Dolphin Internal Battery Pack