Pumpstation Datalogger (2 Pumps)
Multiple Pump Monitoring Low Power Wet Well Levels and Optional Outflow are Recorded
Pump Station Wet Well inflow and outflow analysis
The PD-2 Pump Station Datalogging System is used to capture information pertaining to the flow in and out of a pump station. The flow into the station is calculated by using the wet well level and the wet well volume. With the use of a Data Dolphin datalogger, the PD-2 captures and records the contact closure of a relay to mark a pump start or stop event. Upon a relay’s contact closure or release, the PD-2’s datalogger will record the date, time, wet well level and pump status. Wet well levels (and optional outflow) are also recorded at regular timed intervals. This data is later processed for pump runtime and flow monitoring analysis.
Specifications Analog Inputs Differential Analog Channels: 4 Maximum Input Voltage: +/- 100 mV Analog Voltage Resolution: 0.000,000,090 V A/D Bits: 24 Input Impedance: 20 Gohm Input Bias Current: +/- 9 nA Scan Interval (c): 1.88 to 101 Hz Burst Mode: 101.1 Hz Excitation Channels: 2 Excitation Voltage 1: +2500 mV Excitation Voltage 2: +5000 mV Digital Inputs/Outputs Event or Pulse Channels: 4 General Digital Ports: 3 Input/Output Power Requirements Quiescent Current: 50 uA typical Processing Current: 3 mA Measuring Current: 14 mA Voltage Requirements: 6 to 24 VDC Memory Removable Data Flash Memory: 1 Mb Flash Data Values Stored: 360,448 (Input 1/No time) Temperature Range Standard: -40 to 60°C Extended: -55 to 80°C Dimensions Size (Inches): 8L x 3W x 3.5H Size (cm): 20.32L x 7.62W x 8.89H Weight (Radio module, battery & antenna): 0.918 kg (2.024 lbs) Weight (Battery pack only): 0.778 kg (1.715 lbs) Weight (Alone): 0.564 kb (1.243 lbs)
Enclosure Dimensions Model Hoffman metal electrical enclosure model A-HE10X10X4X (10" x 10" x 4") Width (with door installed) 10 3/8" Height (with door installed) 10 3/8" Weight (Radio module, battery & antenna): 0.918 kg (2.024 lbs) Land Line Modem Specifications Date Rate: 33,600 bit per second Error Correction: Forward error correction MNP 10 Data throughput enhancement for cellular operation Optional Communications Landline modem 33.6K with error correction and data compression. Spread spectrum radio 902 - 928Mhz or 2.4Ghz.
Wireless Internet CDPD radio modem.
Profile Click on image to enlarge
780 450 0591 780 440 2515 (fax) 866 865 9778 (toll free)
#201, 3124 Parsons Road Edmonton, AB T6N 1L6